The Honeywell S9200U1000 can be used with conventional thermostats as well as the EnviraCOM™ enabled VisionPRO IAQ and FocusPRO and is intended for residential natural or liquid propane fueled furnaces only. The S9200U1000 EnviraCOM™ communications capability allows its use in twinning applications and enables communication with local and remote diagnostic devices such as the QuickLook hand held device (QuickLook™ 72), EnviraLINK® web-based application and the W8735D Telephone Access Module (TAM).
Features
The Honeywell S9200U1000's main burner ignition uses a 120V hot surface igniter. The flame rectification circuit allows user to monitor flame presence along with monitoring of system pressure switch, high temperature limit, and rollout functions. Appliance operation/safety requirements are controlled via the microprocessor, while the control of a standard induction-type circulating fan motor (based on appliance requirements), is in response to a conventional low voltage or EnviraCOM™ thermostat. Includes an LED system status, performance and diagnostic indication, wire harnesses for simple replacement of most IFCs and integration with most heating and cooling appliances, twinning capability, and EnviraCOM™ communication capability to enable local and/or remote system status, diagnostics, troubleshooting, and HVAC system control.
Product Specifications
| Description |
Universal single stage heating &
cooling |
| Line Voltage |
120Vac (97-132 Vac) |
| Low Voltage |
24V (18-30Vac) |
| Frequency |
60 Hz |
| Operating Temperature (F) |
-40 F to +175 F |
| Operating Temperature (C) |
-40 C to +79 C |
| Operating Humidity Range (% RH) |
0% to 95% non-condensing |
| Igniter Current |
1.0A resistive @ 95Vac output |
| Thermostat Anticipator Setting
(Stage 1 only) |
100mA |
| PrePurge |
30 seconds |
| HSI Warmup Time |
17/27 or 30/30 seconds |
| Trial For Ignition |
4, 6, or 8 seconds |
| PostPurge |
15 seconds |
| Interpurge |
60 seconds |
| Ignition Trials |
Three, two tries if flame is not
sensed |
| Flame Failure Response Time |
2 Seconds max @ 1µA |
| Number of LEDs |
3 |
| Heat On Fan Delay |
30 or 60 seconds |
| Heat Off Fan Delay |
60, 90, 120, or 180 Seconds |
| Cool Fan On Delay |
5 seconds |
| Cool Fan Off Delay |
0 or 60 seconds |
| Gas Control |
Used With Any 24Vac redundant, direct
ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended. |
| Cooling Contactor |
Used With Any 24Vac contactor rated at
1.0A or less |
| Induced Draft Blower Load |
2.2FLA / 25LRA max @120Vac |
| Circulator Load |
14.5FLA / 25LRA max @120Vac |
| Type of Fan |
Used With Standard Induction-Type
Circulating Fan |