The Honeywell RP920A1033 proportional, high capacity, single or dual input pneumatic controller is used in conjunction with remote sensors to provide proportional (P) or proportional plus integral (P+I) control of temperature, humidity, pressure, or dewpoint for heating and air conditioning systems. Replacement devices are available for Johnson, Powers, Robertshaw, Barber-Colman, and older Honeywell controllers.
Features
The RP920A1033's proportional plus integral control option minimizes offset. Miniature diaphragm technology provides high degree of accuracy and reliability. Direct Acting models can be converted to Reverse Acting (RA) function in field. Includes field-adjustable compensation start point, local or remote setpoint field option, integral action cut-off providing trouble-free automatic startup, optional transparent cover providing protection while allowing easy reading of settings and gages and corrosion resistant construction.
Product Specifications
| Description |
Pneumatic Controller, Remote sensor,
Action: Direct/reverse |
| Application |
Proportional pneumatic controller |
| Remote bulb sensor |
no |
| Number of Sensor Inputs |
single |
| Action Direct |
Acting |
| Airflow Usage |
0.07 scfm (33.0 mL/s) with 1 psi
(7kPa) pressure drop at 18 psi (124 kPa) main air supply |
| Capacity |
at 18 psi (124 kPa) MLP and 8.5 psi
(59 kPa) BLP (does not include sensor usage): 0.021 scfm (10 mL/s) |
| Maximum Safe Operating Pressure
(psi) |
30 psi |
| Maximum Safe Operating Pressure (kPa) |
207 kPa |
| Maximum Operating Temperature (F) |
130 F |
| Maximum Operating Temperature (C) |
54 C |
| Remote Control Point Adjustment |
No |
| Dimensions (in.) |
5 7/8 in. high x 3 13/16 in. wide x 3 1/4 in. without cover x 3 3/8
in. deep with cover |
| Dimensions (mm) |
148 mm high x 96 mm wide x 83 mm without cover x 86 mm deep with
cover |
| Connections |
Air: Combination 5/32 in. by 1/4 in. barb. Optional accessory
14003755-001 (barb fitting for port 4,6,7, or 8 for all RP920). |
| Operating Humidity Range (% RH) |
5 to 95% RH |
| Input Signal (psi) |
3 to 15 psi |
| Input Signal (kPa) |
21 to 103 kPa |
| Output Pressure Range (psi) |
3 to 13 psi, output signal maximum is Mainline Pressure minus 1/2
psi |
| Output Pressure Range (kPa) |
21 to 90 kPa, output signal maximum is Mainline Pressure minus 7
kPa |
| Temperature Range (F) |
40 F to 130 F |
| Temperature Range (C) |
5 C to 55 C |
| Includes |
Without remote control point adjustment capability. |
| Comments |
All RP920s can be converted to reverse acting in the field. For
additional technical information see literature Form no. 85-0224 and 95-7392EF. |
| Maximum Safe Mainline Pressure
(psi) |
30 psi |
| Maximum Safe Mainline Pressure (kPa) |
205 kPa |
| Mainline Pressure Range (psi) |
17 to 21 psi |
| Mainline Pressure Range (kPa) |
115 to 145 kPa |
| Comments on Pressure |
The controller is capable of operating with the MLP (Mainline
pressure) as low as 15 psi (100 kPa) or as high as 23 psi (160 kPa), however
recalibration may be required. |