| Application |
Boiler reset control for hydronic
zoning system |
| Thermostat Compatibility |
AQ1000 Series 2-wire communicating
thermostats |
| Setback Program |
7 day, up to 2 setback periods/day. |
| User Interface (Setting,
Programming) |
LCD Display and a 7 button Key Pad |
| Boiler (Supply) Max. Control
Temperature (F) |
OFF, 120F to 225 F |
| Boiler (Supply) Max. Control
Temperature (C) |
OFF, 49C to 107 C |
| Boiler Min. Control Temperature (F) |
OFF, 59F to 180F |
| Boiler Min. Control Temperature (C) |
OFF, 15C to 82C |
| Outdoor Low Design Control
Temperature (F) |
-60F to 32F |
| Outdoor Low Design Control
Temperature (C) |
-51C to 0C |
| Return Min. Control Temperature (F) |
80 F to 180 F |
| Return Min. Control Temperature (C) |
27C to 82C |
| Boiler Differential |
2F to 41F (1C to 23C), or Auto
(minimum 2 minutes on time) |
| Boiler Heat Post Purge |
Off, 10 seconds to 30 minutes (factory
default is 30 seconds) |
| Pump/Valve exercise |
30 seconds per 2 weeks of space
heating inactivity |
| Power Supply |
120V/60Hz |
| R-C Output (on transformer) |
38 VA, 24 Vac Class II |
| R-C Input (on Control and Zoning
Modules) |
24 Vac Class II (input on Control and
Zoning Modules) |
| Supply/Return Sensor |
Lead Length: 10 ft. (3050 mm). 10
kilohm NTC thermistor at 25 C (77 F) +/- 0.5F (+/-0.3C) up to 500 ft (150 M)
using 18 AWG or larger wire, beta=3892. |
| Auxiliary (Demand) Input |
External dry contacts connection only |
| Heat Demand (Thermostat R-W) Input |
External dry contacts connection only |
| DHW Demand Input |
External dry contacts connection only |
| Boiler (T-T) Output Rating |
24 Vac, 0.5A, 12VA |
| Auxiliary Low Voltage Output Rating |
24 Vac, 0.5A, 12VA |
| B-B Communication Bus Terminals |
Low voltage, Class II, 2-wire
polarity-insensitive, digital communicating link to other Control or Zoning
modules. |
| Boiler Pump Output Rating |
120 Vac/250 Vac 5A, 1/3HP |
| DHW Pump/Valve Output Rating |
120 Vac/250 Vac 5A, 1/3HP |
| Auxiliary Pump Output Rating |
Dry contact output, 120 Vac/250 Vac
5A, 1/3 HP |
| Control and Zoning Panel
Temperature Rating (F) |
32 F to 130 F |
| Control and Zoning Panel
Temperature Rating (C) |
0 C to 55 C |
| Operating Humidity Range (% RH) |
5 to 90% RH, non-condensing |
| Sensor Temperature Rating (F) |
-58 F to +230 F |
| Sensor Temperature Rating (C) |
-50 C to +110 C |
| Dimensions (in.) |
13 in wide x 8 in. high x 3 3/8 in
deep |
| Dimensions (mm) |
33 cm wide x 20.3 cm high x 8.5 cm
deep |
| Weight (kg) |
2.3 kg |
| Weight (lb) |
4.9 lbs |
| Tradeline Value |
Tradeline |
| Number of Non-communicating Zone(s)
Controlled |
1 |
| Type of Zoning Devices Controlled |
None |
| Boiler Design Temperature (F) |
80F to 210F |
| Boiler Design Temperature (C) |
26C to 99C |
| WWSD (Warm Weather Shut Down)
Temperature (F) |
Off, 35 F to 100 F |
| WWSD (Warm Weather Shut Down)
Temperature (C) |
Off, 1 C to 38 C |
| Electrical Connections (Line
Voltage) |
Wire-clamp screw terminals, Maximum 2
x 14 AWG each on line voltage terminals |
| Outdoor Sensor |
Lead Length: 10 ft. (3050 mm). 10
kilohm NTC thermistor at 25 C (77 F) +/- 0.5F (+/-0.3C) up to 500 ft (150 M)
using 18 AWG or larger wire, beta=3892. |
| Replacement Parts |
AQ10X38 24 Vac 38 VA transformer,
AQ12C10 outdoor sensor, AQ12C11 supply/return/mixed loop sensor, AQ1510B0 boiler
reset module |
| Approvals, Canadian Standards
Association |
Certified, File No. LR76030 |